Какво трябва да се провери, когато DC регулираното захранване е повредено?

Oct 29, 2022

Какво трябва да се провери, когато DC регулираното захранване е повредено?


1. Неизправност на линията



2. Изходното напрежение е твърде ниско



1. The load of the adjustable DC stabilized power supply is short-circuit fault (especially the DC/DC converter is short-circuited or has poor performance). At this time, you can first disconnect and adjust all the loads of the adjustable DC stabilized power supply circuit. Make sure the DC stabilized voltage is correct. Is the circuit open or is the load circuit open? If the load circuit is open and the voltage output is normal, it means the load is too heavy. If it is still abnormal, it means that the adjustable DC circuit is faulty.


2. The fault of the filter capacitor or rectifier diode on the output voltage side can be determined by the exchange method.


3. Работата на камерата за гасене на дъга намалява, камерата за гасене на дъга не може да работи нормално, вътрешното съпротивление на захранването се увеличава и товароносимостта намалява.


4. Лошият превключващ трансформатор не само ще намали изходното напрежение, но и ще причини недостатъчно възбуждане на камерата за гасене на дъгата, като по този начин ще повреди камерата за гасене на дъгата.


5. Филтърният кондензатор 300V е дефектен, което ще намали товароносимостта и изходното напрежение на захранването при свързване на товара.


3. The output voltage is too high


Excessive output voltage is usually caused by voltage-stabilized induction circuits and voltage-stabilized control circuits. In a closed loop consisting of a DC output, a sense resistor, an error sense amplifier such as a TL431, an optocoupler, a power control chip, and other circuits, one of the components increases the output voltage. The fuse is normal, no output voltage. If the fuse is normal and there is no output voltage, it means that the adjustable DC stabilized power supply is not working or has entered a protection state. The first step is to check the startup voltage value of the startup pin of the power control chip. If there is no start voltage or the start voltage is too low, check the start pin and external components of the start resistor for leakage. If the power control chip is normal, the above monitoring will help you quickly find the fault. If a startup voltage is applied, it will be measured whether there is a high or low level transition at the output of the control chip when it is turned on. If there is no jump, it means that the control chip is damaged, the components of the peripheral oscillator circuit are damaged, or the protection circuit is faulty. By replacing the control chip, check the peripheral components. If replaced, most switch tubes are broken or damaged.


Четвърто, застраховката се изгаря или взривява


Основно търси токоизправители мостове, диоди, дъгов улей и големи 300 волтови филтърни кондензатори. Предпазителят може да бъде изгорен или почернен, или може да се дължи на проблем с веригата против заглушаване. Специално внимание трябва да се обърне на факта, че повредата на камерата за гасене на дъгата ще издуха предпазителя, като по този начин ще изгори регулируемия чип за управление на постояннотоковото захранване и резистора за откриване на ток. Дори и със застраховка, термисторите могат лесно да изгорят.