В специфични верига на превключване мощност доставка се състои на на следните категории% 3a

Sep 22, 2023

Остави съобщение

В специфични верига на превключване мощност доставка се състои на на следните категории% 3a

 

(1) Buck верига-стъпка надолу чопър% 2c чия изход средно напрежение Uo е по-малко от на вход напрежение Ui и има на същото полярност.


(2) Boost circuit-step-up chopper, whose output average voltage Uo is greater than the input voltage Ui and has the same polarity.


(3) Buck-Boost circuit-buck or boost chopper, whose output average voltage Uo is greater than or less than the input voltage Ui, with opposite polarity and inductive transmission.


(4) Cuk circuit-step-down or step-up chopper, whose output average voltage Uo is greater than or less than the input voltage UI, with opposite polarity and capacitive transmission. Nowadays, soft-switching technology has made a qualitative leap in DC/DC. максимум изход мощност на различни ECI меко превключване DC/DC конвертори проектирани и произведени от американски VICOR Company is 300W, 600W and 800W, и съответстващите мощност плътност is (6, 2, 10, 17)W/cm3, и ефективността is (80-90)%. A високочестотни превключване захранване захранване модул RM серия с soft-switching technology recently въведени от NemicLambda Company of Japan has a switching frequency of (200~300) kHz и a мощност плътност на 27 W% 2fcm3. На синхронен токоизправител (MOS-FET вместо на Schottky диод) е приет , което подобрява ефективността на на цялата верига до 90% 25.


AC/DC конверсия
AC/DC conversion converts AC to DC, and its power flow direction can be bidirectional. The power flow from power supply to load is called "rectification", and the power flow from load to power supply is called "active inverter". The input of AC/DC converter is 50/60Hz alternating current, so it must be rectified and filtered, so a relatively large filter capacitor is necessary. At the same time, due to the restrictions of safety standards (such as UL, CCEE, etc.) and EMC instructions (such as IEC, FCC, CSA), EMC filter must be added to the AC input side and components meeting safety standards must be used, which limits the miniaturization of AC/DC power supply. In addition, Because of the internal high frequency, high voltage and high current switch action, it is more difficult to solve the EMC electromagnetic compatibility problem, which also puts forward high requirements for the internal high-density installation circuit design. For the same reason, the high voltage and high current switch increases the power consumption and limits the modularization process of AC/DC converter. Therefore, the optimization design method of power system must be adopted to achieve a certain degree of satisfaction.


AC/DC преобразуване може бъде разделено на полувълново верига и пълновълново схема според до окабеляване режим на на верига. Според на на брой на мощност фази, it може бъде разделено на единично, трифазно и многофазно. Според на работещо квадрант на на верига, it може бъде разделено на едно квадрант, две квадрант, три квадрант и четири квадрант.

 

Adjustable DC power supply